A door seal that has gone stiff along one edge is where we begin on a KSRA25KK. Warm room air tracks in there, you may see frost or sweating on that side, and the compressor works longer to make up for it. The model is discontinued, and it is also sold as the KSRA25KKBL, KSRA25KKSS and KSRA25KKWH, so we match the seal to your full number.
Next comes the control. When it reads the cabinet wrongly, the compressor runs far longer or far shorter than it should. If a water feed is plumbed in, we inspect the inlet valve and supply line for leaks, and then test the compressor start device, since a failed one makes the compressor hum briefly and drop out on overload.
We quote in writing before beginning, and the 30-day workmanship warranty covers the work.
A stiff seal at that edge lets humid air in, and the moisture freezes on the cold surface. We test the seal, then warm, reseat or replace it and verify the door aligns.
We compare the control's temperature reading with an accurate thermometer inside the cabinet. A gap between them means a sensor or the control itself is off, and we replace the one that disagrees.
Start devices are common parts, but the correct one depends on the compressor. We read the compressor data and the model number before ordering so the replacement matches.