F1 E3 on KitchenAid combination microwave-wall ovens, including the KOCE500ESS and KOCE507ESS, says the microwave appliance manager or its wiring may have a problem. The microwave's coordinating board does not seem to be working properly. You…
F1 E3 on KitchenAid combination microwave-wall ovens, including the KOCE500ESS and KOCE507ESS, says the microwave appliance manager or its wiring may have a problem. The microwave's coordinating board does not seem to be working properly. You see F1 E3 and the upper microwave cavity may not start, while the lower oven may still be fine. While the code shows, microwave settings may reset or ignore your input.
1. Press Cancel. 2. Turn off the breaker for a full minute, restore it, and check that the display wakes normally. 3. Try the microwave with a microwave-safe cup of water for thirty seconds. 4. If F1 E3 is back, do not run the microwave and call us.
No. E1 refers to the oven's appliance manager, while E3 refers to the microwave's. They are separate boards on a combination unit. You can look at the cavity floor and the door seal for spills, but anything inside the cabinet belongs to a technician.
The microwave electronics work harder and with more heat than the lower oven's, so their boards can age differently. The microwave side runs many short, demanding cycles, and heat and use age its boards faster.
Most manager board repairs are done in one visit when the part is available. Parts for popular combination ovens are usually easy for us to source.
A technician diagnoses it on site and gives you the price in writing before any work starts.