Booking today · Houston service windows 9–12 · 1–4 · 4–7 Independent KitchenAid specialists · Licensed & insured Mon–Fri 7:00 AM - 8:00 PM · Sat 8:00 AM - 6:00 PM
(713) 903-2606 Schedule Service
Model library · KitchenAid Refrigerator

KSRS22MW

KitchenAid KSRS22MW Refrigerator Repair

KitchenAid refrigerator

Most common issues on this model

  1. Cold control or thermistor drift that leaves the cabinet warm or freezes the top shelf
  2. Inlet valve weep that forms a slow puddle where few people look
  3. Start relay that has stopped a mechanically sound compressor
  4. Control board wear after long service, so the cabinet no longer follows its settings

Shelves that freeze while the bottom of the KSRS22MW runs warm are a textbook sign of a drifting cold control or thermistor. The cabinet, also sold as KSRS22MWMS, is discontinued, and the sensor is the first thing we compare against a thermometer.

We also look behind the cabinet. A weeping inlet valve may drip slowly enough that no puddle shows from the front. Further along the list sit the start relay, which can stop a healthy compressor, and the control board, which can start ignoring the settings after many years.

The plate may carry a revision code such as KSRS22MWMS02, and we use it to match parts. We work from the simplest check to the most involved, quote in writing before any repair, and stand behind the work with a 30-day workmanship warranty.

Key features

  • Refrigerator
  • Discontinued model
  • Sold in these versions: KSRS22MWMS
  • Codes found on plates: KSRS22MWMS02
→Codes

Error codes this model can show

KSRS22MWKSRS22MW questions
Why does the top shelf of my KSRS22MW freeze food?

A cold control or thermistor that has drifted overcools the upper section. We compare its reading with a thermometer, replace it if it is off, and check airflow through the dampers.

How do you find a slow leak behind a KSRS22MW?

We shut off the water, slide the cabinet forward and inspect the inlet valve and tubing for damp spots. Any weeping part is replaced and the connection is tested under pressure before we push the cabinet back.

What happens if the relay on my KSRS22MW fails?

The compressor will not start even though it is mechanically sound, so the cabinet warms up. We test the relay and overload, replace the failed part, and confirm the compressor runs normally.

Book a visit

Book repair for your KSRS22MW

Book in about a minute, or call the desk. Same-day windows inside the Loop on most days, next-day across the rest of Houston.

☎ Call the desk ▤ Schedule Service