In a KBRC36MH that never seems to settle, we suspect the temperature sensing first. Sensors age and drift, and the control then cools to a wrong target. We put a reference thermometer inside and compare it with what the control reports.
Some plates read KBRC36MHW for this cabinet. If it is connected to a water supply, we also check the valve, the line and the filter housing, as slow leaks here wet the floor behind the cabinet.
A click every few minutes with no cooling suggests the start relay or overload, which we test before the compressor. When the cabinet runs but ignores the panel, the electronic control is the next stop. We give you a written price first, and we cover our work with a 30-day workmanship warranty.
We place a calibrated thermometer in the compartment for a full cycle and compare its readings with the control. If they disagree, we test the sensor resistance and replace it.
The inlet valve or a fitting is likely dripping while the valve is open. We watch each connection during a fill, tighten or replace what seeps, and dry the area afterward.
Not always. The click is usually the relay switching, and the compressor is not responding. We test the relay and overload first because they are cheaper to correct than the compressor.